Commissioning forms

Please complete the relevant commissioning forms per property.

Once finished, these will automatically route to NexGen

Commissioning Document Electrical Installation

Property Address(Required)
MM slash DD slash YYYY

NEXGEN INSURED GUARANTEE - Electrical Installation

Please Tick as appropriate
Please confirm all PSUs, cabling, crimp connectors, thermostats and thermostat receivers have been supplied by NexGen and installed in accordance with manufacturer instructions and/or training provided by NexGen.(Required)
Please confirm that all installed PSUs have adequate ventilation and spacing and that the placement of each PSU has been considered as part of the installation.(Required)
Please confirm continuity has been tested for the installed mats and that a full circuit is being completed.(Required)
Please confirm the resistance for each heating mat circuit is of a comparable value across each room and that any anomalies have been investigated and rectified as part of the installation.(Required)
Please confirm each mat is receiving between 23-27 volts. Should a lower or higher value be found, please check wiring connections and rectify.(Required)
Please confirm all regulation guidelines have been worked to during this installation.(Required)
Please confirm circuit supplying the spurs for the NexGen PSUs has been installed on its own dedicated circuit(s) supplied from a Type D/C RCD/RCBO which has a higher amp rating than the installed system as found on the mat layout provided.(Required)